![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/c5/0c571298-6899-4cf2-95ab-2b8a3cf7f957/0c571298-6899-4cf2-95ab-2b8a3cf7f957-bgf1.png)
EPSON Stylus Pro 7600/9600 Revision A
Adjustment Self-diagnostic Function 241
FEED CORRECTION + T&B ADJUSTMENT
1. Start the Self-diagnostic Function:
Power OFF →
[Paper Feed
∆
]
+
[Paper Feed
∇
]+[Cut/Eject] → Power ON
2. Display “Adj: Feed Adj.+T&B”:
[Paper Feed
∇
]
→
[SelecType >]
→
[Paper Feed
∆
] x6
3. Print the pattern.
[SelecType >]
→
[Enter
↵
]
when “[Enter] Adjust Print” is displayed
(See Figure
5-32)
4. Measure the top margin:
Using a measuring rule, measure the top margin. Input the measured value on the
panel.
5. Measure the bottom margin:
Using a measuring rule, measure the bottom margin. Input the measured value on the
panel.
6. Measure the side margin:
Using a measuring rule, measure the side margin. Input the measured value on the
panel.
7. Measure the feed correction value:
Using a measuring rule (1000 mm) and the scale stopper, measure the longitudinal line
length. Input the measured value on the panel.
Figure 5-33. Print Pattern for Feed Correction + T&B Adjustment
C H E C K
P O I N T
The central print pattern among the patterns as shown above is
intended for use as a datum line on which the measuring rule is
to be placed.
Even if you have left the “Feed Correction + T&B Adjustment”
mode by mistake, you can restore the relevant adjustment
display without reprinting the pattern, by pressing [Paper
Source <] when “[Enter] Adjust Print” is displayed.
Top margin (3.0mm)
Side margin
(3.0mm)
Bottom margin (14.0mm)
Longitudinal line length (1000.0mm)
Paper Feed Direction