A SERVICE OF

logo

Chapter 3
15
3 Installing Additional Components
Safety Information
This chapter describes installing additional or optional hardware to your hp Integrity cx2600 Server.
Follow the procedures listed below to ensure safe handling of components and to prevent harm to both you
and the HP Server:
Use an antistatic wrist strap and a grounding mat, such as those included in the Electrically Conductive
Field Service Grounding Kit (HP 9300-1609).
Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or
any electrical components on accessory boards.
Do not wear clothing that is subject to static charge build-up, such as wool or synthetic materials.
WARNING Hazardous energy is present inside the HP Server. Always remove power from
the server before working inside the unit. Serious injury may result if this
warning is not observed.
Service Tools Required
Service of this product may require one or more of the following tools:
Electrically Conductive Field Service Kit (P/N 9300-1609)
1/4 inch flat blade screwdriver
ACX-15 torx screwdriver
ACX-10 torx screwdriver
IPF CPU install tool (P/N 5069-4551—supplied with processors shipped separately)
Accessing a Rack Mounted Server
The hp Integrity cx2600 Server is designed to be rack mounted. The following procedure explains how to gain
access to an hp Integrity cx2600 Server that is mounted in an approved rack.
WARNING Ensure that all anti-tip features (front and rear anti-tip feet installed; adequate
ballast properly placed, and so on) are employed prior to extending the server.