5700 Step Top Wood Stove Series ACC
7. Snap Disc Location
If you fi nd the blower coming on and off at undesirable
temperatures, relocate the snap disc to another location
in the designated zone on the back of the appliance.
Figure 15.2. There is a manual over-ride switch to
deactivate the snap disc, if necessary. See page 45
for location of over-ride switch.
N. Blower Operating Instructions
Figure 15.1
Figure 15.3
O. Clear Space
Do NOT place combustible objects within 4 ft (1.2 m) of
the front of appliance. See Figure 15.3.
WARNING! Do NOT place combustible objects in front
of the appliance. High temperatures may ignite clothing,
furniture or draperies.
Mantel - avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage these
objects.
1. Initial (cold) startup: Open both controls fully by rais-
ing the Burn Rate Air Control all the way up until it stops
and slide the Start-up Air Control back until it stops.
The
blower tends to cool the appliance. Leave the blower off
until the burn is well established, i.e., 30 minutes.
2. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is
fully pushed in. Blower may remain on.
3. Medium or Medium High Burn Setting*: Burn Rate
Air Control is closed then opened to 1 inch to fully open.
Blower may remain on.
4. Medium Low Burn Setting*: Burn Rate Air Control is
closed then opened to 1/4 inch to 1/2 inch.
Leave the
blower off until the burn is well established, i.e., 30 min-
utes.
5. Low Burn Setting*: Burn Rate Air Control is closed.
Leave the blower off until the burn is well established, i.e.,
30 minutes.
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled back to acti-
vate the Automatic Combustion Control (ACC).
NOTE: For maximum effi ciency and lowest emissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards “OFF” as far as
possible without turning the blower off. For a low blower
speed, turn the control knob clockwise as far as pos-
sible
NOTE: If your Quadra-Fire wood appliance is equipped with
an optional blower, you should follow these guidelines:
Up (Open)
Down (Closed)
Start-Up Air
Control
Burn Rate
Air Control
Push to Open
Pull back to
activate ACC
Figure 15.2 - Snap Disc Location
Maintain 4 ft clearance to com-
bustible in front of appliance