R
5700 Step Top Wood Stove Series ACC
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
• Wind loading possible
Figure 27.1
E. Chimney Termination Requirements
Follow manufacturer’s instructions for clearance, secur-
ing fl ashing and terminating the chimney.
Must have an approved and Listed cap
Must not be located where it will become plugged
by snow or other material
Must terminate at least 3 feet (91cm) above the
roof and at least 2 feet (61cm) above any portion
of the roof within 10 feet (305cm).
Must be located away from trees or other struc-
tures
D. Locating Your Stove & Chimney
Location of the appliance and chimney will affect perfor-
mance. As shown in Figure 27.1 the chimney should:
Install through the warm space enclosed by the build-
ing envelope. This helps to produce more draft, espe-
cially during lighting and die down of the fi re.
Penetrate the highest part of the roof. This minimizes
the affects of wind turbulence and down drafts.
Consider the appliance location in order to avoid
oor and ceiling attic joists and rafters.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstruc-
tions.
Your local dealer is the expert in your geographic area and
can usually make suggestions or discover solutions that will
easily correct any fl ue problems you may encountered.
NOTICE:
Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect
performance.
Chimney height may need adjustment if smoking or
overdraft occurs.
NOTICE: Locating the appliance in a basement or in a location
of considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near
Frequently open doors
Central heat outlets or returns
NOTICE
BEFORE INSTALLATION OF THIS APPLIANCE, CON-
TACT YOUR LOCAL MUNICIPAL BUILDING DEPART-
MENT, FIRE DEPARTMENT, FIRE PREVENTION
BUREAU, OR OTHER AUTHORITY HAVING JURIS-
DICTION TO DETERMINE THE NEED TO OBTAIN A
PERMIT.