![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/49/b49b521c-2e86-4110-b392-684b20d3dd6a/b49b521c-2e86-4110-b392-684b20d3dd6a-bg23.png)
31
AUTO SETUP
PREPARATION
■ Troubleshooting for the auto setup procedure
Before auto setup
During auto setup
Press l / h to display detailed information for individual errors. Select Retry to try the auto setup procedure again.
Error message Cause Remedy
Connect MIC! Optimizer microphone is not connected. • Connect the supplied optimizer microphone to the
OPTIMIZER MIC jack on the front panel.
Unplug Phones! Headphones are connected. • Unplug the headphones.
No Setup Menu! No setup menu items have been selected. • Select at least one setup menu item.
Memory Guard! This setting is protected. • Remove the protection setting for auto setup
(see page 68).
Error message Cause Remedy
E01:No Front SP Front L/R channel signal(s) is (are) not
detected.
• Select the front speakers by pressing
SPEAKERS A or B on the front panel
(or by setting AMP/SOURCE/TV to AMP,
then pressing SPEAKERS A or B on the remote
control).
• Check the front L/R speaker connections.
E02:No Sur. SP Only one surround channel signal is detected. • Check the surround speaker connections.
E03:No Pres. SP Only one presence channel signal is detected. • Check the presence speaker connections.
E04:SBR ->SBL Only the surround back right channel signal is
detected.
• Connect the surround back speaker to the LEFT
SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.
E05:Noisy Background noise is too loud. • Try auto setup in a quiet environment.
• Turn off noisy electric equipment like air
conditioners, or move them away from this unit.
E06:Check Sur. Surround back speaker(s) is (are) connected,
though surround L/R speakers are not.
• Connect surround speakers when using (a) surround
back speaker(s).
E07:No MIC The optimizer microphone was unplugged
during the auto setup procedure.
• Connect the supplied optimizer microphone to the
OPTIMIZER MIC jack on the front panel.
E08:No Signal The optimizer microphone does not detect test
tones.
• Check the microphone setting.
• Check the speaker connections and placement.
E09:User Cancel The auto setup procedure was cancelled
because a setting that affects auto setup (such as
changing speaker settings, etc.) was changed
during the procedure.
• Perform the auto setup procedure again.
E10:Internal Err An internal error occurred. • Restart this unit, then try the auto setup procedure
again.