Chapter 8 Basic Setting
GS2200-24 User’s Guide
88
Click the PoE Setup link in the Basic Setting > PoE Status screen. The
following screen opens.
Figure 46 Basic Setting > PoE Setup
The following table describes the labels in this screen.
Table 15 Basic Setting > PoE Setup
LABEL DESCRIPTION
PoE Mode Select the power management mode you want the Switch to use.
• Classification - Select this if you want the Switch to reserve the Max
Power (mW) to each PD according to the priority level. If the total
power supply runs out, PDs with lower priority do not get power to
function.
• Consumption - Select this if you want the Switch to manage the total
power supply so that each connected PD gets a resource. However, the
power allocated by the Switch may be less than the Max Power (mW) of
the PD. PDs with higher priority also get more power than those with
lower priority levels.
Port This is the port index number.
PD Select this to provide power to a PD connected to the port.
If left unchecked, the PD connected to the port cannot receive power from
the Switch.