Lucent Technologies 20 Cell Phone Accessories User Manual


 
Configuring a 20 Series CellPipe
Configuring WAN interface
4-6 CellPipe 20 Series Users Guide
Select the rx_bin command to limit the bin number used for special configurations
in the receive signal. Values for bin numbers are between 1 to 255.
>adsl> rx_bin - <start_bin> <end_bin>
Select the show command to display the ADSL parameter configuration. For
example:
>adsl> show
ADSL setting: Current Ineffective
Local line code MULTIMODE MULTIMODE
Trellis encoding Enabled Enabled
EC/FDM mode FDM FDM
Coding gain AUTO 2 dB
Transmit Power Attenuation 0 dB 0 dB
Tx Start bin 6 (H) 6 (H)
Tx End bin 1f (H) 1f (H)
Rx Start bin 20 (H) 3 (H)
Rx End bin ff (H) 4 (H)
Select the startup command to restart the ADSL connection.
>adsl> startup
start to re-Sync. ...
Select the status command to display the ADSL parameter configuration. For
example:
>adsl> status
ADSL Firmware version ANNEX_A CPE 41000
OP state handshake
Last Failed Status (0)
Start Progress a0
Watchdog Timer 53
Line code
G.DMT
Framing_Overhead_actual 0
Trellis <disable>
AS0_Dn_Bytes_Actual 0