Sharp SGH-T519 Cell Phone User Manual


 
SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting
10-11
This Document can not be used without Samsung's authorization
10-1-5. Microphone Part
Micro-phone does not work
Is the connection status of
HDC300 O.K?
YES
Reconnect connector of HDC300
NO
Check the DC bias voltage on
Mic path.
The voltage of C406 is
about 2.2V±10%?
NO
Solder the microphone again
or Replace
R406, R415, R418, R425
Is microphone OK?
NO
Check UCD301
END
YES
YES