Section 2: Installing the 1700 Reader In-Sight
®
1700 Series Wafer Reader
6
2.1.2 Connecting the Breakout Cable
The In-Sight Breakout Cable (P/N 300-0340-15) included with every 1700 wafer reader
provides access to the 1700 reader’s power, serial communications, and I/O lines. The
RJ-45 connector on this cable is “keyed” to the notch in the breakout port, and cannot be
inadvertently plugged in to the network port.
See Section 8.2.1: Breakout Port Pin Assignments on page 90 for the Breakout Cable’s
wiring details.
To connect the Breakout Cable to the In-Sight 1700 reader:
1 Verify the 24VDC power supply being used is switched off.
2 Attach the Breakout Cable’s power (white-green wire) and ground (brown wire) to the
corresponding terminals on the power supply.
3 Connect the wires for the acquisition trigger, discrete outputs, and serial
communications to their corresponding terminals on remote devices.
4 Plug the RJ-45 connector into the 1700 reader’s breakout port (labeled 24VDC).
5 Restore power to the 24V supply. The green power LED will indicate that the reader
is receiving power.
2.1.3 Connecting the Breakout Module
The optional In-Sight Breakout Module (P/N 800-5743) is more convenient than using the
standard Breakout Cable to connect the reader’s power, serial communications, and I/O
lines.
For additional information on connecting a Breakout module, see Section 8.2.1: Breakout
Port Pin Assignments on page 90 or the Breakout Module Installation and Reference
manual (P/N 597-0008-xx).
Figure 2-2: Breakout Module Connections