A SERVICE OF

logo

Section 7: Native Mode Commands In-Sight
®
1700 Series Wafer Reader
74
7.5.2 GetConfigResult
GetConfig(<WafID>,<Config>)
Returns the results of the most recent read performed by the specified Config.
Inputs: WafID, Config
Outputs: Status Code, # of bytes, Passed, String, Score, TryLog, TuneLog, LastRead,
NumPassed, NumFailed, NumTunePassed, NumTuneFailed, AvgScore, High, Wide,
Theta, Char (Orc), Value (Orc), Row (Orc), Col (Orc)
Sample Input and Output
EV GETCONFIGRESULT(A4,0)
1
1701
<Result Id="0">
<Passed>1</Passed>
<String>6713H129S6A1</String>
<Score>396</Score>
<TryLog>1</TryLog>
<TuneLog>0</TuneLog>
<LastRead>10</LastRead>
<NumPassed>4</NumPassed>
<NumFailed>0</NumFailed>
<NumTunePassed>0</NumTunePassed>
<NumTuneFailed>0</NumTuneFailed>
<AvgScore>96</AvgScore>
<High>40</High>
<Wide>21</Wide>
<Theta>0</Theta>
<Orc Id="0">
<Char>54</Char>
<Value>96</Value>
<Row>51</Row>
<Col>25</Col>
</Orc>
<Orc Id="1">
<Char>55</Char>
<Value>96</Value>
<Row>51</Row>
<Col>65</Col>
</Orc>
<Orc Id="2">
<Char>49</Char>
<Value>98</Value>
<Row>52</Row>
<Col>105</Col>
</Orc>
<Orc Id="3">
<Char>51</Char>
<Value>97</Value>
<Row>53</Row>
<Col>145</Col>
</Orc>
<Orc Id="4">
<Char>72</Char>
<Value>99</Value>
<Row>53</Row>
<Col>187</Col>
</Orc>
<Orc Id="5">
<Char>49</Char>
<Value>99</Value>
<Row>54</Row>
<Col>228</Col>
</Orc>
<Orc Id="6">
<Char>50</Char>
<Value>94</Value>
<Row>54</Row>