![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/8e/f8ecd953-447b-4c07-93aa-494c94814826/f8ecd953-447b-4c07-93aa-494c94814826-bgb4.png)
5. Examine the bulk power supply (BPS) LEDs (Figure C-14).
When on, the breakers on the PDCA distribute power to the BPSs. Power is present at the
BPSs when:
• The amber LED labeled AC0 Present is on (if the breakers are on the PDCA on the left
side at the back of the cabinet).
• The amber LED labeled AC1 Present is on (if the breakers are on the PDCA on the right
side at the back of the cabinet).
Figure C-14 BPS LEDs
Powering On the System Using the PE Command
To power on the system, follow these steps:
1. From the Command Menu, enter the pe command.
IMPORTANT: If the complex has an IOX cabinet, power on this cabinet first.
In a large complex, power on the cabinets in one of the two following orders:
• 9, 8, 1, 0
• 8, 9, 0, 1
2. Enter B and then the cabinet number (Figure C-15).
180 Powering the System On and Off