⎯ 117 ⎯
6 F 2 S 0 8 5 7
initiated and the following display appears. The input and output signals of the timer can be
observed at monitoring jacks A and B respectively. The LEDs above monitoring jacks A or B
are also lit if the input or output signal exists.
/2 Timer
Operating...
Press END to reset.
PressCANCELtocancel.
• Press the
END
key to reset the input signal to the timer. The "TESTING" LED turns off.
• Press the
CANCEL
key to test other timers. Repeat the above testing.
4.2.7.4 Logic Circuit
It is possible to observe the binary signal level on the signals listed in Appendix B with monitoring
jacks A and B.
• Press 4 (= Logic circuit) on the "Test" screen to display the "Logic circuit" screen.
g
2 L o i c c i r c u i t 1
2
T e r m A ( 0 - 0 7 1 ) : 1 3
T e r m B
0- 071
:48
3
• Enter a signal number to be observed at monitoring jack A and press the
ENTER
key.
• Enter the other signal number to be observed at monitoring jack B and press the
ENTER
key.
After completing the setting, the signals can be observed by the binary logic level at monitoring
jacks A and B or by the LEDs above the jacks.
On screens other than the above screen, observation with the monitoring jacks is disabled.