A SERVICE OF

logo

6–16
SCANTEAM 3700 Wedge Technical Manual
Message Length
We recommend setting the minimum and maximum message lengths
according to the smallest range [Minimum, Maximum] the application allows.
The start/stop and check characters should not be counted. This will also help
minimize the chance of a misread. Defaults on default chart at the end of this
manual.
Note: To select digits 0 through 9 use the Programming Chart found on the
inside of theback cover of thismenu. Scanthe programmingselection bar code
first, and then scan the bar code(s) representing the digits you wish to set.
Code 128
Code 128 is a continuous, edgeĆtoĆedge symbology capable of encoding
variableĆlength messages from the full 128Ćcharacter ASCII set. Through the
use of mode switching, the extended 256Ćcharacter ASCII set can be encoded,
and doubleĆdensity numerics are possible. Each Code 128 character is eleven
modules wide, and is comprised of three bars and three spaces. Its characters
are spatially efficient.
The Code 128 specification requires the use of one check character; the
symbology is highly secure. Default = On.
Code 128
Code 128
StartĂ/ĂStop Characters
Termination Bar
Check Character
Code 128
On
Off
Message
Length
Maximum ]Minimum ]
] A twoĆdigit number is required after scanning this programming bar code.
Please scan your selection on the Programming Chart (inside back cover).
Programming Tip: If a symbology won't be used, we recommend turning it off
to minimize the chance of a misread.