Ericsson LBI-38965B Cell Phone User Manual


 
INSTALLATION LBI-38965
31
These parameters are defined using the BCU/CAL Configuration Service (BCS) program. BCS is discussed in detail in
LBI-38967. The following example is provided for reference to get the BCU set up and running as quickly as possible.
PREREQUISITE
1. Obtain the IMC slot number of the NIM and PIM modules, if any.
2. If not already logged into the BCU/CAL, log in under the "root" account as previously discussed. Enter the
following commands at the indicated prompts.
USER INFORMATION: Entering "bcs" invokes the BCS program.
pSH+> bcs
Welcome to the BCU-CAL Configuration Service (BCS)
System Administrator privilege acknowledged.
USER INFORMATION: Entering "show system" displays the default system parameters that were initialized
during the initial software installation.
BCS> show system
Default unit pseudo hangtime = 10
Default group pseudo hangtime = 10
Default group billing mode = Bill callee
Data call pseudo hangtime = 10
Data call billing = On
Phone digits mandatory = Off
CDR maximum file records = 1024
CDR sequence wrapping = On
Offload time = 00:00:00
Tape logging = Off
CDR archive(s) lifetime = 7
IMC time synchronization = Off
System ID = 0
Node ID = 0
NIM slot = 0
PIM slot = 0
USER ACTION: To define the IMC NIM slot, execute the following command. This example assumes that the
NIM occupies slot 32. The actual value should reflect the end user's IMC configuration. If the IMC does not
have a NIM, disregard this command.
BCS> set system /nim = 32
USER ACTION: To define the IMC PIM slot (for Jessica), execute the following command. This example
assumes that the PIM occupies slot 16. The actual value should reflect the end user's IMC configuration. If the
IMC does not have a PIM, skip this command.
BCS> set system /pim = 16