Fujitsu MB3891 Cell Phone Accessories User Manual


 
MB3891
12
(Continued)
(Ta = +25 °C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V)
Parameter Symbol Pin No. Conditions
Value
Unit
Min. Typ. Max.
SIM
interface
5 V
(SIMPROG
= H)
Output voltage
V
OH 36 RST (max.) = 20 µA
VSIMOUT
0.7
VSIMOUT
V
V
OL 36 RST (max.) = 200 µA0 0.6 V
Rise time T
R 36 RESET-IN = RST = 30 pF 400 µs
Fall time TF 36 RESET-IN = RST = 30 pF 400 µs
Output voltage
V
OH 37 CLK (max.) = 20 µA
0.7 ×
VSIMOUT
VSIMOUT V
V
OL 37 CLK (max.) = 200 µA0 0.5 V
Rise time TR 37 CLK-IN = CLK = 30 pF 27 ns
Fall time T
F 37 CLK-IN = CLK = 30 pF 27 ns
Output voltage
V
OH 38 SIM-IO (max.) = 20 µA3.8 VSIMOUT V
VOL 38 SIM-IO (max.) = 1 mA 0 0.4 V
Input voltage
V
IH 38
0.7 ×
VSIMOUT
VSIMOUT V
V
IL 38 0 0.8 V
Rise time TR 38 SIM-IO = 30 pF 1 µs
Fall time T
F 38 SIM-IO = 30 pF 1 µs
SIM
interface
3 V
(SIMPROG
= L)
Output voltage
V
OH 36 RST (max.) = 20 µA
0.8 ×
VSIMOUT
VSIMOUT V
V
OL 36 RST (max.) = 200 µA0
0.2 ×
VSIMOUT
V
Rise time TR 36 RESET-IN = RST = 30 pF 400 µs
Fall time T
F 36 RESET-IN = RST = 30 pF 400 µs
Output voltage
V
OH 37 CLK (max.) = 20 µA
0.7 ×
VSIMOUT
VSIMOUT V
VOL 37 CLK (max.) = 200 µA0
0.2 ×
VSIMOUT
V
Rise time T
R 37 CLK-IN = CLK = 30 pF 50 ns
Fall time T
F 37 CLK-IN = CLK = 30 pF 50 ns
Output voltage
VOH 38 SIM-IO (max.) = 20 µA
0.7 ×
VSIMOUT
VSIMOUT V
V
OL 38 SIM-IO (max.) = 1 mA 0 0.4 V
Input voltage
V
IH 38
0.7 ×
VSIMOUT
VSIMOUT V
V
IL 38 0
0.2 ×
VSIMOUT
V
Rise time TR 38 SIM-IO = 30 pF 1 µs
Fall time T
F 38 SIM-IO = 30 pF 1 µs