3745 MAPs
009 (continued)
Is the 3745 still powered ON?
Yes No
010
Go to “CE Leaving Procedure” on
page 4-102.
011
– Power the 3745 OFF as follows:
Set the power control to local mode:
– Using Power Control, scroll till the
value is 3.
– Press Validate.
Press Power Off.
– Turn the CB1 OFF.
– Re-install the PCC card.
– Exchange the MCC card (01A-X0H). Refer to
Figure 4-9 on page 4-11.
– Turn the CB1 ON.
– Press Power On Reset.
– Set the power control to network mode.
Using Power Control, scroll till the value is
2.
Press Validate.
– Select the IFT diagnostics and run routine
AT05.
Is the 3745 still powered ON?
Yes No
012
Go to “CE Leaving Procedure” on
page 4-102.
013
– Power the 3745 OFF as follows:
Set the power control to local mode:
– Using Power Control, scroll till the
value is 3.
– Press Validate.
Press Power Off.
– Re-install the MCC card (01A-X0H).
– Exchange the PUC card (01G-V).
– Set the power control to network mode.
Using Power Control, scroll till the value is
2.
Press Validate.
– Select the IFT diagnostics and run routine
AT05.
(Step 013 continues)
013 (continued)
Is the 3745 still powered ON?
Yes No
014
Go to “CE Leaving Procedure” on
page 4-102.
015
– Re-install the PUC card (01G-V).
You have gone through the entire procedure and
the problem is still present. Contact your support
structure for further assistance.
Chapter 2. Map for FRU Isolation 2-29