Control Programming
PROGRAM
ITEM
KEY SEQUENCE
DISPLAY
1
Low Cook
Temp Lockout
Press left basket to increase or right basket to decrease cooking cycle lockout
temperature (range 30 to 50F)
2
NOTE: Prevents cook timers from starting if actual shortening temperature is
not within the lockout temperature setting.
LOCKO 40
(always in °F)
NOTE: The program items listed below are for verifying settings only. Do not change the default setting for these
program items.
PROGRAM
ITEM
KEY SEQUENCE
DISPLAY
1
Instant On
Time (heat)
Press left basket to increase or right basket to decrease instant on time.
NOTE: At the start of a cook cycle, the heat output will be activated for this time
(range 0 to 20 seconds).
INSTO 20
Melt Cycle On/
Off Times
Press left basket to increase or right basket to decrease melt cycle time.
3
Gas Fryers
Adjustment Range:
Melt ON - 0 to 20 seconds; Melt OFF - 0 to 30 seconds.
MLTG
1 16
(Liq)
08
(Sol)
(Melt
ON)
MLTG
0 18
(Liq)
26
(Sol)
(Melt
OFF)
Electric Fryers
Adjustment Range:
Melt ON - 0 to 2 seconds; Melt OFF - 10 to 30 seconds.
MLTE1
04
(Liq)
02
(Sol)
(Melt
ON)
MLTE0
11 (liq)
13
(Sol)
(Melt
OFF)
Proportional
Offset
Press left basket to increase or press right basket to decrease proportional
offset (range 0 to 30).
POFST 02
Proportional
Gain
Press left basket to increase or right basket to decrease proportional gain (range
0 to 30).
PGAIN 24
Derivative Gain
Press left basket to increase or right basket to decrease derivative gain (range
0 to 30).
DGAIN 20
Integral Gain
press left basket to increase or right basket to decrease integral gain (range 0
to 30).
IGAIN 08
Integral Limit
Press left basket to increase or right basket to decrease integral limit (range 0
to 255).
ILIM 255