COMPONENT FUNCTION - KLEENSCREEN FILTER CONTROLS
Fill Solenoid Valve ... When energized by filter key, the solenoid valve opens to allow the flow of shortening
thru filtering system.
Pump Motor .......... Operates pump to circulate shortening through filtering system.
Drain Valve Interlock
Switch (DVI) ..........
A magnetic reed switch mounted on the mechanical discard valve that closes when
discard valve handle is extended to discard the shortening. Prevents R2 filter relay N.C.
contacts from suppling power to the fill solenoid valve when filter key is pressed.
R1 Pump Motor Relay ...When 24VAC relay coil is energized by filter key, supplies 120VAC to pump motor; and
fill solenoid valve (thru R2 fill relay N.C. contacts.
R2 Fill Relay ......... When 24VAC relay coil is energized by filter key, supplies 24VAC to the fill solenoid valve
to open the valve and allow shortening to flow thru filter system.
COMPONENT LOCATION
Fig. 66
Fig. 67
Fig. 68
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - ELECTRICAL OPERATION
Page 41 of 55 F45474 (0413)