Fig. 62
If the spark igniter rod is not adjusted correctly the gas
could build up in the burner assembly and cause a
delayed ignition of the burner. The resulting "puffing"
could result in damage to the fryer.
NOTE: If the power supply box has been converted
to the new controls, the spark igniter rod should be
replaced with the new style spark rod.
SPARK GAP SETTING AFTER
12/1/12
1. Insure the spark igniter is installed properly on
the burner.
2. The spark igniter rod should be set touching
mesh or with a maximum gap between rod and
burner mesh of 1/16 of an inch.
Fig. 63
3. There should be a gap of 1/8 to 3/16 of an inch
between igniter rod and ground rod.
Fig. 64
4. This igniter sparks to the ground rod. To insure
we have a proper ground, we put a wire on the
ground rod terminal and secure it to burner.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - SERVICE PROCEDURES AND ADJUSTMENTS
F45474 (0413) Page 38 of 55