3-6
1. Rotate the ENTER knob to select “SIG DET S LEVEL”.
2. Press the ENTER knob to display the S LEVEL pop-up window.
S LEVEL (OFF 255)
SIG DET S LEVEL pop-up window
3. Rotate the ENTER knob to adjust the indicator bar. Too low a setting stops transmission
of a DSC message because it detects noise on the DSC frequency. Alternately, too high
a setting transmits the DSC message though low signal level is present on the DSC
frequency used.
4. Press the ENTER knob to finish.
REGULATION
Set the regulation to be used.
1. Rotate the ENTER knob to select “REGULATION”.
2. Press the ENTER knob.
INTL
RUSSIA
Regulation pop-up window.
3. Rotate the ENTER knob to select “INTL” or “RUSSIA”.
Only for Russia registry, select “RUSSIA”.
4. Press the ENTER knob to finish.
CLASS
Set the watch receiver function as below.
1. Rotate the ENTER knob to select “CLASS”.
2. Press the ENTER knob to display the pop-up window.
MF/HF
MF
NONGM
Class pop-up window
3. Select “MF/HF” or “MF” as appropriate.
MF/HF: Maximum six distress/safety frequencies are available. (A1, A2, A3 and A4 area)
MF: Distress/safety frequency is 2187.5 kHz only (A1 and A2 area).
NONGM: Not used.
4. Press the ENTER knob to finish.
DIST
Shows the last transmitted DISTRESS information.