B. Reduced Air Flow
Installation of the equipment in a rack should
be such that the amount of air flow required
for safe operation of the equipment is not
compromised. To ventilate the system nor-
mally and avoid overheating, leave at least
1 inch (2.5 cm) on each side (including top
and bottom) of the OAT100R. Do NOT stack
other equipment on the top of the OAT100R.
Also, ensure that the unit’s AC power adapter
is never stacked or bundled with other AC
power adapters. Each adapter should have
adequate ventilation and should be isolated
from other heat sources.
C. Circuit Overloading
Consideration should be given to the
connection of the equipment to the supply
circuit and the effect that overloading of the
circuits might have on overcurrent protection
and supply wiring.
D. Reliable Earthing
Maintain reliable earthing of rack-mounted
equipment. Particular attention should be
given to supply connections other than direct
connections to the branch circuit (e.g., use of
power strips).
E. Mains Outlet Earthing
The apparatus with Class I construction must
be connected to a mains socket outlet with a
protective earthing connection.
OAT100R Server Installation on a Flat Surface
To install the
OAT100R
on a level surface (table
top, shelf, etc.):
• Install the equipment in an environment
compatible with the maximum operating
ambient temperature (Tma) specied by the
manufacturer (see Specications information
in this document).
• Place spacers or rubber feet (not provided) on
the bottom of the
OAT100R
.
• Carefully place the
OAT100R
on the level
surface.
• To ventilate the system normally and avoid
overheating, leave at least 1 inch (2.5 cm) on
each side (including top and bottom) of the
OAT100R. Do NOT stack other equipment on
the top of the OAT100R.