A SERVICE OF

logo

50
206-4218
(Continued from previous page)
Available output modes:
1 - RF
2 - IP
Enter number of new output mode [1]>
2. At the prompt, either press Enter to accept the default value (i.e., the current setting) in
square brackets, or type the number that corresponds to the appropriate output mode and
press Enter.
The system will conrm your selection, for example:
Output mode is set: RF
3. Complete the appropriate conguration, depending on the output mode. Refer to “Congure
the RF Output” on page 54 or “Congure the IP Output” on pages 56 to 59, as applicable.
Configure the Program PIDs
If any Pro:Idiom channels are configured in the site’s entertainment system, you must configure
program PIDs for the OAT100R output. See “Packet Identifiers (PIDs) Overview” on page 10 for
further information, and/or check with your service representative, if necessary.
1. At the
Setup Command >
prompt, type pid and press Enter.
The system displays an overview of the current PID conguration (including Pro:Idiom
PIDs) followed by a prompt for the starting program PID, for example:
Current PID Configuration
Program PIDs range: 0x30 - 0x6f
Pro:Idiom PIDs range: 0x1050 - 0x1057
Send Pro:Idiom messages: no
Enter the starting program PID [0x30]:
2. At the prompt, type the new starting program PID in hexadecimal format, and then press
Enter.
Note: The system will auto-increment the remaining 63 program PIDs from the starting PID.
Note: If any of the program PIDs conflicts with PIDs that have been set/reserved for
Pro:Idiom, the system will display an error message and then return to the starting
program PID prompt.
If you change the starting program PID, the system will display an overview of the new
configuration and prompt for confirmation, for example:
Conguration Options via Command Line (Cont.)
(Continued on next page)