A SERVICE OF

logo

44 Rockwell Automation Publication 1412-UM001D-EN-P - September 2012
Chapter 3 Display Modes
Select a Graphic Display for Recorded Measurements
Recorded data can be displayed in graphic form.
Select the recording to be displayed by using the Up/Down Cursor buttons.
Then, open the recording by pressing Enter.
Use the function buttons to enable direct selection of the measurement to be
displayed.
Pressing ../.. lets you scroll through all the measurements selected when the
record was programmed.
Example When Vrms is Selected
Display of the average voltage for each of the three voltages. Moving the
cursor with the Left/Right Cursor buttons updates the values to reflect the
new cursor position.
Selection of the three phases or each phase separately with the Up/Down
Cursor buttons.
Returns to the screen where the measurement to be displayed is selected.
07/25/02 10:56 100
%
RECORDING
F Urms UthdUcf Vrms ../..
SELECTION OF MEASUREMENT TO VIEW
START :
07/25/02
17:58
END :
07/25/02
18:27
PERIOD :
1 mn
(1%)
TEST
220.0V
210.0V
200.0V
mn>
Vrms
10 15 20 25 30
203.4
v
204.7
v
204.0
v
3L
L1
L2
L3
07/25/02 10:38 100
%
07/25/02 10:13:21
1
2 3
2
1
3