015 MACHINE IS
NOT LEVEL
The Lower Control has detected the machine has all
four outriggers on the ground but is not level.
This is a self clearing error. When error condition is
removed, error is cleared.
Possible causes include:
1. Machine has gone out of level with use
2. Faulty level sensor
3. Faulty level sensor wiring
4. Faulty Lower Control
1. Check outrigger and level LED indicators and if
required re-level machine
2. Check level sensor
3. Repair or replace level sensor wiring
4. Replace Lower Control
016 LIFT BOOM
The Lower Control has detected the Boom must be
raised before the requested function can be
performed.
This is a self clearing error. When error condition is
removed, error is cleared.
Possible causes include:
1. Trying to rotate boom while boom is down
2. Trying to extend boom while boom is down
3. Trying to retract boom while boom is down
4. Faulty boom down limit switch
5. Faulty boom down limit switch wiring
6. Faulty Lower Control
1. Check that boom is raised before trying to rotate
boom
2. Check that boom is raised before trying to extend
boom
3. Check that boom is raised before trying to retract
boom
4. Check and repair boom down limit switch
5. Repair or replace boom down limit switch wiring
6. Replace Lower Control
017 STOW BOOM
The Lower Control has detected the boom must be
lowered before the requested function can be
performed.
This is a self clearing error. When error condition is
removed, error is cleared.
Possible causes include:
1. Trying to auto level machine while boom is
raised
2. Trying to extend outriggers while boom is raised
3. Trying to retract outriggers while boom is raised
4. Faulty boom down limit switch
5. Faulty boom down limit switch wiring
6. Faulty Lower Control
1. Check that boom is down before trying to auto
level machine
2. Check that boom is down before trying to extend
outriggers
3. Check that boom is down before trying to retract
outriggers
4. Check and repair boom down limit switch
5. Repair or replace boom down limit switch wiring
6. Replace Lower Control
018 LOSS OF LOAD SENSE
COMMUNICATION
The Lower Control has lost communication with the
Load Sense Module.
This is a latched error. To clear this error, first the
error condition must be removed and second the
power must be cycled off then back on.
NOTE: During this error condition, the Load Sense
Module "Status" LED will blink a red “2 blink” error
code and the Lower Control “Power” LED will blink a
“5 blink” error code.
NOTE: This error only occurs on machines equipped
with the Load Sense option.
Possible causes include:
1. Lower control incorrectly configured
2. Faulty Boom Cable
3. Faulty Load Sense Module
4. Faulty Lower Control
1. Correctly configure Lower Control
2. Replace Boom Cable
3. Replace Load Sense Module
4. Replace Lower Control