Error Message
Displayed
Error Explanation &
Possible Causes
What To Check &
Corrective Action To Clear
Error
083 OPEN CIRCUIT
DRIVE ENGAGE
The Lower Control has detected an open circuit on the
Drive Engage solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Drive Engage solenoid wiring
2. Faulty Drive Engage solenoid
3. Faulty Lower Control
1. Repair or replace Drive Engage solenoid
wiring
2. Replace Drive Engage solenoid
3. Replace Lower Control
084 SHORTED
CIRCUIT
DRIVE ENGAGE
The Lower Control has detected excessive current on the
Drive Enable solenoid output when it was energized
during startup self diagnostics.
Possible causes include:
1. Faulty Drive Engage solenoid wiring
2. Faulty Drive Engage solenoid
3. Faulty Lower Control
1. Repair or replace Drive Engage solenoid
wiring
2. Replace Drive Engage solenoid
3. Replace Lower Control
085 OPEN CIRCUIT
LEFT WHEEL
FORWARD
The Lower Control has detected an open circuit on the
Left Wheel Forward solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Left Wheel Forward solenoid wiring
2. Faulty Left Wheel Forward solenoid
3. Faulty Lower Control
1. Repair or replace Left Wheel Forward
solenoid wiring
2. Replace Left Wheel Forward solenoid
3. Replace Lower Control
086 SHORTED
CIRCUIT
LEFT WHEEL
FORWARD
The Lower Control has detected excessive current on the
Left Wheel Forward solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Left Wheel Forward solenoid wiring
2. Faulty Left Wheel Forward solenoid
3. Faulty Lower Control
1. Repair or replace Left Wheel Forward
solenoid wiring
2. Replace Left Wheel Forward solenoid
3. Replace Lower Control
087 OPEN CIRCUIT
LEFT WHEEL REVERSE
The Lower Control has detected an open circuit on the
Left Wheel Reverse solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Left Wheel Reverse solenoid wiring
2. Faulty Left Wheel Reverse solenoid
3. Faulty Lower Control
1. Repair or replace Left Wheel Reverse
solenoid wiring
2. Replace Left Wheel Reverse solenoid
3. Replace Lower Control
088 SHORTED
CIRCUIT
LEFT WHEEL REVERSE
The Lower Control has detected excessive current on the
Left Wheel Reverse solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Left Wheel Reverse solenoid wiring
2. Faulty Left Wheel Reverse solenoid
3. Faulty Lower Control
1. Repair or replace Left Wheel Reverse
solenoid wiring
2. Replace Left Wheel Reverse solenoid
3. Replace Lower Control