Error Message
Displayed
Error Explanation &
Possible Causes
What To Check &
Corrective Action To Clear
Error
024 SHORTED CIRCUIT
PRIMARY DOWN
The Lower Control has detected excessive current on
the Primary Down solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Primary Down solenoid wiring
2. Faulty Primary Down solenoid
3. Faulty Lower Control
1. Repair or replace Primary Down solenoid
wiring
2. Replace Primary Down solenoid
3. Replace Lower Control
025 OPEN CIRCUIT
SECONDARY UP
The Lower Control has detected an open circuit on the
Secondary Up solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Secondary Up solenoid wiring
2. Faulty Secondary Up solenoid
3. Faulty Lower Control
1. Repair or replace Secondary Up solenoid
wiring
2. Replace Secondary Up solenoid
3. Replace Lower Control
026 SHORTED CIRCUIT
SECONDARY UP
The Lower Control has detected excessive current on
the Secondary Up solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Secondary Up solenoid wiring
2. Faulty Secondary Up solenoid
3. Faulty Lower Control
1. Repair or replace Secondary Up solenoid
wiring
2. Replace Secondary Up solenoid
3. Replace Lower Control
027 OPEN CIRCUIT
SECONDARY DOWN
The Lower Control has detected an open circuit on the
Secondary Down solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Secondary Down solenoid wiring
2. Faulty Secondary Down solenoid
3. Faulty Lower Control
1. Repair or replace Secondary Down solenoid
wiring
2. Replace Secondary Down solenoid
3. Replace Lower Control
028 SHORTED CIRCUIT
SECONDARY DOWN
The Lower Control has detected excessive current on
the Secondary Down solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Secondary Down solenoid wiring
2. Faulty Secondary Down solenoid
3. Faulty Lower Control
1. Repair or replace Secondary Down solenoid
wiring
2. Replace Secondary Down solenoid
3. Replace Lower Control
029 OPEN CIRCUIT
JIB UP
The Lower Control has detected an open circuit on the
Jib Up solenoid output when it was energized during
startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Jib Up solenoid wiring
2. Faulty Jib Up solenoid
3. Faulty Lower Control
1. Repair or replace Jib Up solenoid wiring
2. Replace Jib Up solenoid
3. Replace Lower Control
030 SHORTED CIRCUIT
JIB UP
The Lower Control has detected excessive current on
the Jib Up solenoid output when it was energized
during startup self diagnostics.
Possible causes include:
1. Faulty Jib Up solenoid wiring
2. Faulty Jib Up solenoid
3. Faulty Lower Control
1. Repair or replace Jib Up solenoid wiring
2. Replace Jib Up solenoid
3. Replace Lower Control