4 – OPERATOR SERVICE
37
Error Message
Displayed
Error Explanation &
Possible Causes
What To Check &
Corrective Action To Clear
Error
031 OPEN CIRCUIT
JIB DOWN
The Lower Control has detected an open circuit on the Jib
Down solenoid output when it was energized during
startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Jib Down solenoid wiring
2. Faulty Jib Down solenoid
3. Fault Lower Control
1. Repair or replace Jib Down solenoid wiring
2. Replace Jib Down solenoid
3. Replace Lower Control
032 SHORTED CIRCUIT
JIB DOWN
The Lower Control has detected excessive current on the
Jib Down solenoid output when it was energized during
startup self diagnostics.
Possible causes include:
1. Faulty Jib Down solenoid wiring
2. Faulty Jib Down solenoid
3. Faulty Lower Control
1. Repair or replace Jib Down solenoid wiring
2. Replace Jib Down solenoid
3. Replace Lower Control
033 OPEN CIRCUIT
EXTEND
The Lower Control has detected an open circuit on the
Extend boom solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Extend boom solenoid wiring
2. Faulty Extend boom solenoid
3. Faulty Lower Control
1. Repair or replace Extend boom solenoid
wiring
2. Replace Extend solenoid
3. Replace Lower Control
034 SHORTED CIRCUIT
EXTEND
The Lower Control has detected excessive current on the
Extend boom solenoid output when it was energized
during startup self diagnostics.
Possible causes include:
1. Faulty Extend boom solenoid wiring
2. Faulty Extend boom solenoid
3. Faulty Lower Control
1. Repair or replace Extend boom solenoid
wiring
2. Replace Extend solenoid
3. Replace Lower Control
035 OPEN CIRCUIT
RETRACT
The Lower Control has detected an open circuit on the
Retract boom solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Retract boom solenoid wiring
2. Faulty Retract boom solenoid
3. Faulty Lower Control
1. Repair or replace Retract boom solenoid
wiring
2. Replace Retract boom solenoid
3. Replace Lower Control
036 SHORTED CIRCUIT
RETRACT
The Lower Control has detected excessive current on the
Retract boom solenoid output when it was energized
during startup self diagnostics.
Possible causes include:
1. Faulty Retract boom solenoid wiring
2. Faulty Retract boom solenoid
3. Faulty Lower Control
1. Repair or replace Retract boom solenoid
wiring
2. Replace Retract boom solenoid
3. Replace Lower Control