VISORNET - Installation
I-8
Doc. DM245-I
Rev. 7.0
I - 2.2.1. Input connections
ZONE 0
ZONE 1
ZONE 3
ZONE 2
ZONE 5
ZONE 4
4
1
3
2
ON
5
6
7
8
ON
4
1
3
2
ON
4
1
3
2
ON
4
1
3
2
ON
4
1
3
2
ON
4
1
3
2
ON
4
1
3
2
SW1
SW3
Figure 1.5. Configuration microswitches for the six zones in the underside cover
of the device
In the inputs you can connect: a relay, a press button or an interrupter (whether these
are normally opened or normally closed, supervised or not), a voltage source or
current source.
To connect an input To disconnect
Extract the plugable lead
corresponding to the input you
wish to connect on the rear
panel of the device.
Disconnect the plugable lead from
the connector located on the rear
panel of the device.
Put the stripped cable into
from the device relay into the
lead screwing this in securely.
Unscrew and pull out the lead cable.
Configure the microswitch
corresponding to the input.
Plug the lead into connector located
on the rear panel of the device.
Plug the lead into the device’s
rear panel connector.