A SERVICE OF

logo

VISORNET Appendix
II-36
Doc. DM245-I
Rev. 7.0
After a few seconds, the updated devices will re-start in order to activate the new code
version.
If you wish to update the application software, press the APPLICATION button (see
figure 1.20). The process is identical to the BIOS procedure. The header field
changes to “Uploading the APPLICATION...” indicating that the process is
executing. This will change to “Uploaded equipments with Application” once the
process has completed. In this case another screen will also appear summarizing the
results of the uploading, displaying the devices which have correctly updated in green
and those that have not in red.
Similarly, after a few seconds the updated devices will re-start in order to active the
new application software version.
Important: Do not manually re-start the device during the interval
between the uploading and the automatic device re-start. This may leave
the device inoperable.
The configuration parameters described in the following paragraphs are
the specific to each device. To access these parameter configuration forms, you need
to previously select the device you wish by clicking on the icon representing the said
device.
II - 2. Technical Specifications
Hardware Architecture
PROCESSORS
Motorola MPC 860T - 32 bits with CPM at 66 MHz.
MEMORY 32 Mbytes RAM, 512 Kbytes RAM non volatile
STORAGE UNIT FLASH memory (4 Mbytes).
Eeprom memory: 2 Kbytes.
Vídeo
Nº OF INPUTS
4, through BNC connectors, 1V
pp
/ 75
TYPE NTSC (RS-170) or PAL (B and G) synchronous or non
synchronous
DIGITALIZATION FORMATE Maximum resolution of 320x240 pixels (NTSC) and 352x288
pixels (PAL)
MAXIMUM DIGITALIZATION RATE
WITH ONE ACTIVE INPUT
25 images per second
AGGREGATED DIGITALIZATION
RATE WITH FOUR ACTIVE
INPUTS
12.5 images per second
COMPRESSION JPEG ISO 1092-2
ITU H.263 optional
MPEG4 SP ISO/IEC 14496-2