6.29 Set relative horizontal print position “ESC (/ nL nH n1 n2 m1 m2”
Format:
ASCII ESC ( / nL nH n1 n2 m1 m2
Hex 1B 28 2F nL nH n1 n2 m1 m2
Decimal 27 40 47 nL nH n1 n2 m1 m2
Range of Values for Parameters:
nL=04H, nH=00H
0 <= (m4*1000000H +m3*10000H + m2*100 + m1))×(relative horizontal print position
set unit)inch <= 11904/1440inch or
If bit 7 of m4 is 1,this is taken to mean that a negative value has been set.
Function:
1) If bit 7 of m4 is 1, this is taken as meaning that a negative value has been set.
Negative values are expressed in two's complement.
2) The printing position in the X direction is set to a position spaced in the positive
direction from the present printing position in the X direction by (m4×256×256×
256 +m3×256×256 + m2×256 + m1) x (the set relative horizontal position setting
unit).
Set the defined unit with the ESC (U command.
The default defined unit for this command is 1/60inch.
If the position setting due to this command is within the non-printable region, it is
ignored. However, it is possible to shift to a position on the right margin position.
This command is only effective in graphics mode.
Initial State: -
Related Commands:
Commands related in the direction of applying an effect (Setting)
None
Commands related in the direction of receiving an effect (Setting)
None
Commands related in the direction of applying an effect (Operation)
None
Commands related in the direction of receiving an effect (Operation)
None