698
Chapter 34 CAN Controller
2.Register Description
recovery sequence, the Error Management Counters will be reset.
(Note) During the waiting time after the resetting of Init, each time a sequence of 11 recessive bits has
been monitored, a Bit0Error code is written to the Status Register, enabling the CPU to readily
check up whether the CAN bus is stuck at dominant or continuously disturbed and to monitor the
proceeding of the busoff recovery sequence.
Status Register (STATR)
res res res res res res res res
Bit no.
Read/write
(R) (R) (R) (R) (R) (R) (R) (R)
Default value
(0) (0) (0) (0) (0) (0) (0) (0)
Status Register high byte
Address : Base + 0x02
H
15 14 13 12 11 10 9 8
STATRH
BOff EWarnEPassRxOK TxOK LEC
Bit no.
Read/write
(R) (R) (R) (R/W) (R/W) (R/W) (R/W) (R/W)
Default value
(0) (0) (0) (0) (0) (0) (0) (0)
Address :
Base + 0x
03H
765432 10
STATRL
Status Register low byte