Chapter 37 Output Compare
4.Registers
bit0: Enable operation requests (output compare 0)
A bit that enables a comparison operation between the free-run timer count value and the output
compare register (TCDT0 and OCCP0).
Before enabling the operation, always set a value to compare register OCCP0.
If you stop the free-run timer, output compare also stops.
CST0 Operation
0 Disable output compare 0 operation
1 Enable output compare 0 operation