A SERVICE OF

logo

ES-4024A User’s Guide
38 Chapter 2 Hardware Installation and Connection
2.2 Mounting the ES-4024A on a Rack
This section lists the rack mounting requirements and precautions and describes the
installation steps.
2.2.1 Rack-mounted Installation Requirements
Two mounting brackets.
Eight M3 flat head screws and a #2 Philips screwdriver.
Four M5 flat head screws and a #2 Philips screwdriver.
Note: Failure to use the proper screws may damage the unit.
2.2.1.1 Precautions
Make sure the rack will safely support the combined weight of all the equipment it
contains.
Make sure the position of the ES-4024A does not make the rack unstable or top-heavy.
Take all necessary precautions to anchor the rack securely before installing the unit.
2.2.2 Attaching the Mounting Brackets to the ES-4024A
1 Position a mounting bracket on one side of the ES-4024A, lining up the four screw holes
on the bracket with the screw holes on the side of the ES-4024A.
Figure 7 Attaching the Mounting Brackets
2 Using a #2 Philips screwdriver, install the M3 flat head screws through the mounting
bracket holes into the ES-4024A.
3 Repeat steps 1 and 2 to install the second mounting bracket on the other side of the ES-
4024A.
4 You may now mount the ES-4024A on a rack. Proceed to the next section.
2.2.3 Mounting the ES-4024A on a Rack
1 Position a mounting bracket (that is already attached to the ES-4024A) on one side of the
rack, lining up the two screw holes on the bracket with the screw holes on the side of the
rack.