A SERVICE OF

logo

Chapter 32 Introducing the Commands
VES-1616F-3x Series User’s Guide
239
maxpower ds <0..58> Specify the maximum aggregate
power level for downstream
transmission.
13
us <0..58> Specify the maximum aggregate
power level for upstream
transmission.
13
optusage <1..2> Sets the use of optional channel
for the upstream or downstream
traffic.
1: unused
2: upstream
13
payloadrate maxdsfast
<64..104960>
Specifies the maximum
downstream fast channel data
rate in bits/second.
13
maxdsslow
<64..104960>
Specifies the maximum
downstream slow channel data
rate in bits/second.
13
maxusfast
<64..104960>
Specifies the maximum upstream
fast channel data rate in bits/
second.
13
maxusslow
<64..104960>
Specifies the maximum upstream
slow channel data rate in bits/
second.
13
mindsfast
<64..104960>
Specifies the minimum
downstream fast channel data
rate in bits/second.
13
mindsslow
<64..104960>
Specifies the minimum
downstream slow channel data
rate in bits/second.
13
minusfast
<64..104960>
Specifies the minimum upstream
fast channel data rate in bits/
second.
13
minusslow
<64..104960>
Specifies the minimum upstream
slow channel data rate in bits/
second.
13
pbo uscontrol <1..3> Sets the upstream PBO control.
1: Disable
2: Auto
3: Manual
13
uslevel <0..120> Sets the upstream PBO level. 13
psdtemplate ds <1..2> Sets a PSD mask for the
downstream traffic.
13
us <1..2> Sets a PSD mask for the
upstream traffic.
13
ratemode ds <1|2> Sets a rate adaptive mode for the
downstream traffic
1: Manual
2: AdaptAtInit
13
Table 85 vdsl-profile Commands (continued)
COMMAND DESCRIPTION P