A SERVICE OF

logo

Chapter 6 Basic Setting
VES-1616F-3x Series User’s Guide
65
6.3 General Setup
Click Basic Setting and General Setup in the navigation panel to display the screen as shown.
Use this screen to configure the system name, the system time and date and specify the login
authentication database priority.
Current This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX This field displays this fan's maximum speed measured in Revolutions Per Minute
(RPM).
MIN This field displays this fan's minimum speed measured in Revolutions Per Minute
(RPM).
Threshold This field displays the minimum speed at which a normal fan should work.
Status Normal indicates that this fan is functioning above the minimum speed. Error
indicates that this fan is functioning below the minimum speed.
If Error displays, it is recommended that the fan(s) on the switch be replaced by a
qualified technician.
Voltage (V) The power supply for each voltage has a sensor that is capable of detecting and
reporting if the voltage falls out of the tolerance range.
Current This is the current voltage reading.
MAX This field displays the maximum voltage measured at this point.
MIN This field displays the minimum voltage measured at this point.
Threshold This field displays the percentage tolerance of the voltage with which the switch still
works.
Status Normal indicates that the voltage is within an acceptable operating range at this
point; otherwise Error is displayed.
If Error displays, an electronic component might be defective. Have the switch
serviced by a qualified technician.
Poll Interval(s) The text box displays how often (in seconds) this screen refreshes. You may change
the refresh interval by typing a new number in the text box and then clicking Set
Interval.
Stop Click Stop to stop port statistic polling.
Table 9 System Info (continued)
LABEL DESCRIPTION