A SERVICE OF

logo

xStack DES-6500 Modular Layer 3 Chassis Ethernet Switch CLI Manual
Example usage:
To delete an SNMP host entry:
DES-6500:4#delete snmp host 10.48.74.100 public
Command: delete snmp host 10.48.74.100 public
Success.
DES-6500:4#
show snmp host
Purpose Used to display the recipient of SNMP traps generated by the
Switch’s SNMP agent.
Syntax
show snmp host {<ipaddr>}
Description
The show snmp host command is used to display the IP
addresses and configuration information of remote SNMP
managers that are designated as recipients of SNMP traps that
are generated by the Switch’s SNMP agent.
Parameters
<ipaddr> The IP address of a remote SNMP manager that will
receive SNMP traps generated by the Switch’s SNMP agent.
Restrictions None.
Example usage:
To display the currently configured SNMP hosts on the Switch:
DES-6500:4#show snmp host
Command: show snmp host
SNMP Host Table
Host IP Address SNMP Version Community Name/SNMPv3 User Name
--------------- --------------------- ------------------------------
10.48.76.23 V2c private
10.48.74.100 V3 authpriv public
Total Entries: 2
DES-6500:4#
create trusted_host
Purpose Used to create the trusted host.
Syntax
create trusted_host <ipaddr>
Description
The create trusted_host command creates the trusted host.
The Switch allows specification up to four IP addresses that are
allowed to manage the Switch via in-band SNMP or TELNET
based management software. These IP addresses must be
members of the Management VLAN. If no IP addresses are
specified, then there is nothing to prevent any IP address from
accessing the Switch, provided the user knows the Username
and Password.
45