Lucent Technologies 3000 Carrying Case User Manual


 
Software Upgrading
7-8 Issue 1 October 1998
How to Upgrade Software Using a Terminal Program
continued
Procedure
The module displays the following messages:
Last chance to stop... will force restart after upgrade.
Do you want to continue?
Enter Y to continue, any other key to abort.
3. Enter Y to continue. The message displays:
Please wait while flash memory is being checked…
The erase process takes about 15 seconds. The message
Erasing Flash Memory displays as Flash ROM is being
prepared to receive the new code.
The message Successfully erased displays.
The screen then displays the following message:
Please upload (to Extender) the S Record file using
ASCII transfer protocol.
Waiting for upload file...
4. Select ASCII, or text file, upload protocol and select the
S-record file (*.hex format) to upload to the module.
Note: You have 60 seconds to do this.
The module then displays the following message:
Starting upload, have received and written up to line...
100
200