A SERVICE OF

logo

Black 0015
Black0015
PROGRAMMING DIFFERENT SENSOR TYPES
Follow the instructions on the previous page
to select a sensor number to program the
sensor into.
NOTE: A sensor can be programmed into more
than one location. Be sure to choose an unused
sensor number. If a sensor gets entered into more
than one location, delete the duplicates using the
remove sensor function.
To add DXS-10 wireless keypads, press and
hold the keypad’s [
] key until programmed
into the Console.
IMPORTANT NOTE: The DXS-31 door/window
sensors are pre-set at the factory for delayed
burglary response. If the sensor is going to be
used on a non-entry portal (window, sliding glass
door, etc.) a jumper can be changed in the sensor
to select instant response. The jumper should be
changed before learning the sensor so the
Console will program the sensor to the proper
zone. See the “Basic Sensor Installation” section
of this manual for details on changing the jumper.
For DXS-31 door/window sensors, press the
case or move the magnet away from the side
of the sensor.
For DXS-81, DXS-91, DXS-54, DXS-71 &
DXS-72 accessory sensors, simply send a test
transmission (refer to the sensor’s instructions
for details on sending a test transmission).
For DXT-61, DXT-21 & DF-41 single-button
remotes, simply press the unit’s button. The
unit will function as an arm/disarm remote.
NOTE: After the Console “learns” the transmitter,
single-button remotes can easily be
re-programmed as “panic buttons” or home
automation controllers. Refer to the “Customizing
the System” section of this manual.
For DXT-23 & DF-42 two-button remotes:
Learn the transmitter by pressing the left
button. The remote will arm/disarm the Console
with the left button and activate/deactivate the
home automation output with the right button.
Labels are provided with the DF-42 for
identifying the buttons.
NOTE: After the Console “learns” the transmitter,
two-button remotes can easily be re-programmed
to have the left button arm the Console and the
right button disarm the Console. Refer to the
“Advanced Programming” section of this manual.
A single “bing” tone will sound and the sensor
status indicator will stay lit when the sensor is
learned by the Console.
A double “buzz” tone will sound if there is
already another sensor programmed to that
sensor number.
Exit Setup Mode by holding the [
OFF
] button for
two seconds. Reminder: The Console will
automatically exit the Setup Mode and return to
Off Mode after 3 minutes of keypad inactivity.
NOTE: To remove sensors from the Console’s
memory, see the “Customizing the System”
section of this manual.
SEND SIGNAL WITH LEFT BUTTON
LEFT = ARM/DISARM
RIGHT = AUTOMATION
BOTH = EMERGENCY
13