COMMUNICATOR REPORTING CODES
The two-digit communicator reporting code
for each event has a factory set value. These
values may be customized to fit the specific
installation and the reporting requirements of
the Central Station monitoring the system.
If Point ID reporting is enabled (the factory
default setting), each sensor can report a
unique alarm and trouble code.
If Point ID is disabled, the “general” reporting
codes for each event type will be used.
Each programming function is performed with
similar keystrokes. After the Console is in
Setup Mode, enter the programming step
number, press the [
HOME
] key (HOME =
program), enter the new value, and press the
[
AWAY
] key (AWAY = store).
Making a value 0 causes event to not
communicate to central station.
NOTE: The reporting codes are fixed for opening
and closing. A unique code is reserved for the
master, the five restricted, and page alert user
codes. See the Opening & Closing Reporting
Codes Table.
GENERAL REPORTING CODES
Program Steps #201 - 206 for the
communicator reporting codes when Point ID
is disabled.
Refer to the Console & General Reporting Codes
table to view/edit the reporting codes for each of
the five events. The factory settings are listed,
along with a blank area to write in the new
installation values.
Any value from 0-99 can be programmed for
each event (0 = no report).
NOTE: Be careful not to duplicate codes unless
the Central Station requires specific codes for
certain types of events.
SYSTEM REPORTING CODES
Program Steps #261 - 266 for the Console
reporting codes.
Refer to the System Reporting Codes table to
view/edit the reporting codes for the keypad
[FIRE] and [EMERGENCY] buttons and for each
of the four Control Panel conditions. The factory
settings are listed, along with a blank area to
write in the new installation values.
GENERAL REPORTING CODES
STEP #
PROGRAMMING
FUNCTION
POSSIBLE
VALUES
FACTORY
VALUE
INSTALLATION
VALUE
201 GENERAL FIRE REPORT CODE 0 - 99 1
202 GENERAL EMERGENCY REPORT CODE 0 - 99 2
203 GENERAL SILENT PANIC REPORT CODE 0 - 99 3
204 GENERAL BURGLARY REPORT CODE 0 - 99 4
206 GENERAL TROUBLE REPORT CODE 0 - 99 6
General Reporting Codes Table
HOME
TEST
= PROGRAM
= REMOVE
AWAY
= STORE
0
HOME
AWAY
0 - 99 FOR GENERAL
ALARM REPORTING CODE
PROGRAMMING STEPS
#201 TO #206
PROGRAM
STORE PROGRAM
2
ABC
6
MNO
HOME
AWAY
0 - 99 FOR SYSTEM
REPORTING CODE
PROGRAMMING STEPS
#261 TO #266
PROGRAM
STORE PROGRAM
2
ABC