A SERVICE OF

logo

Black 0042
Black0042
4 BY 2 FORMAT POINT ID REPORTING CODES
4 BY 2 FORMAT POINT ID ALARM REPORT CODES
Refer to the 4 by 2 Format Point ID Reporting
Code table to view/edit the alarm reporting
codes for each of the 12 sensors. The
communicator will send these codes if Point
ID is enabled and any sensor triggers an
alarm. The factory settings are listed, along
with a blank area to write in the new
installation values.
NOTE: Be careful not to duplicate codes unless
the Central Station requires specific codes for
certain types of sensors.
Each programming function is performed with
similar keystrokes. After the system is in
Setup Mode, enter the programming step
number, press the [
HOME
] key (HOME =
program), enter the new value, and press the
[
AWAY
] key (AWAY = store).
4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES
Refer to the 4 by 2 Format Point ID Reporting
Code table to view/edit the trouble reporting
codes for each of the 12 sensors. The
communicator will send these codes if Point
ID is enabled and any sensor has a low battery
or trouble condition. The factory settings are
listed, along with a blank area to write in the
new installation values.
NOTE: Be careful not to duplicate codes unless
the Central Station requires specific codes for
certain types of sensors.
Each programming function is performed with
similar keystrokes. After the Console is in
Setup Mode, enter the programming step
number, press the [
HOME
] key (HOME =
program), enter the new value, and press the
[
AWAY
] key (AWAY = store).
0 - 99 FOR SENSOR
ALARM CODE
(0 = NO REPORT)
PROGRAMMING STEPS
#210 TO #221
PROGRAM
STORE PROGRAM
0 - 99 FOR SENSOR
TROUBLE CODE
(0 = NO REPORT)
PROGRAMING STEPS
#234 TO 245
PROGRAM
STORE PROGRAM
DVS12K24.EPS
40