2. SECURITY SYSTEM FLOOR PLAN
EXAMPLE SYSTEM
◆ The example shows a typical DVS-1200
system.
◆ Any or all of the accessories shown can be
used.
◆ A total of 12 sensors (including keypads) can
be used with each Console.
DESIGN THE INSTALLATION
Create a floor plan of the installation.
Consider the security needs of the premises.
Determine which doors and windows are
vulnerable to intrusion.
Figure which interior areas an intruder might
go to if unlawful entrance is gained.
Indicate locations for door/window sensors,
interior motion detectors, keypads, glass
break detectors and external siren speakers.
Decide on a centralized location for the
security Console.
CON
MS
ES
WK
S
S
S
MD
MS
S
MS
CON - CONSOLE
S - DOOR/WINDOW SENSOR
WK - WIRELESS KEYPAD
MD - MOTION DETECTOR
ES - EXTERNAL SIREN
SD - SMOKE DETECTOR
GB - GLASS BREAK SENSOR
MS - EXTERNAL MAGNETIC SWITCH
LIVING
DINING
KITCHEN
ENTRY
BED
BATH
GB
SD
BED
NOTE: IN
NEW
CONSTRUCTION, NFPA 71 REQUIRES A
SMOKE DETECTOR LOCATED
INSIDE
EACH BEDROOM
AS WELL AS A SMOKE DETECTOR ON EACH LEVEL.
Example Residential Security System Floor Plan