10 AUXILIARY FUSE
★
Type 2AG, 1-amp fuse.
★
Protects the external relay output when used with wet contacts (12 VDC
switched out).
★
Fuse will blow when load exceeds 1 amp.
✍
WARNING: For continued protection against the risk of fire, replace
only with the same type and rating of fuse.
11 MAIN TERMINAL BLOCK
★
Terminals for connection to the plug-in AC transformer.
★
Terminals for connection to an external siren speaker.
★
Automation Output to connect to an automation controller.
★
External relay output for “wet” contacts (switched 12 volts) or “dry” contacts
(normally open 1 amp @ 24 volts maximum).
12 BATTERY FUSE
★
Type 2AG, 3-amp fuse for the backup battery.
★
If the POWER light is flashing and the optional backup battery is installed
and charged, check this fuse.
✍
WARNING: For continued protection against the risk of fire, replace
only with the same type and rating of fuse.
13 TELEPHONE TERMINAL BLOCK
★
Provides telephone connections for the digital communicator.
★
Provides seized ring and tip connections for local telephone instruments.
Communicator will disconnect local telephones while on-line.
14 INTERNAL SPEAKER CONNECTOR
★
Connects the internal speaker to the Console circuit board.
★
2-pin connector, non-polarized.
15 ANTENNA TERMINALS
★
Antenna and ground terminals for receiving signals from the system’s
sensors.
★
Pre-wired to the Console’s internal wire dipole antenna.
★
Alternately connects to the Model LA-P local whip and remote antenna kit.
16 OPTIONAL BACKUP BATTERY
★
Space for 12-volt, 1.2 amp/hour backup battery. (Highly recommended.)
★
Backup battery is automatically charged and monitored by the Console.
★
Backup battery can power the Console for up to 6 hours.
★
UL NOTE: Normal estimated battery life should be 3 to 4 years.
17 WIRING ACCESS HOLE
★
Provides access to recessed wiring trough in base of Console.
★
Route cables for power, telephone, external speaker, etc. through this hole.
★
Loop for zip-tie strain relief provided next to hole.
18 WALL-MOUNT SLOTS
★
Used when mounting Console recessed in the wall.
★
Two mounting brackets (supplied) slide through slots and are retained by
screws, clamping the unit to the wall.
19 RADIO TEST POINTS
★
Used to monitor the Console’s radio receiver during troubleshooting.
★
Provides connection for an audio amplifier to listen to the receiver’s output.
★
Helpful to determine sources of radio interference.
20 MICROPHONE (WITH MODEL VB-2 INSTALLED ONLY)
★
High sensitivity microphone.
★
Detects room audio when communicator is reporting to the Central Station
in 2-way audio mode (Model VB-2 must be installed).
21 ANNUNCIATOR VOLUME CONTROL
★
Varies the volume of the advisory tones that come from the speaker.
★
Does not affect internal or external sirens (they are always full volume).
22 DIGITAL VOICE SYNTHESIS MODULE (OPTIONAL)
★
Two voice synthesis modules are available, the Model VB-2 and VB-3.
★
Both modules allow remote command of the Console using a standard
pushbutton telephone, on or off site.
★
Both modules provide optional human voice prompts from the Console’s
speaker.
★
The Model VB-2 gives the Console’s digital communicator listen-only,
manual 2-way and full duplex 2-way audio capability with the Central
Station.