Black0022
TEST MODE
Even though this is a self-monitoring
supervised system, the National Burglar and
Fire Alarm Association recommends that all
security systems should be tested manually
on a regular basis.
The Console must be in Off Mode before going
to Test Mode.
Switch the Console into Test Mode by entering
a user code and pressing [
TEST
].
When the system is switched to the Test
Mode, the Console will sound a “Gong” and
four “Beeps”.
Holding down the [
TEST
] button in Test Mode
will light all of the Console’s indicators.
The sensor status lights will flash for each
sensor programmed into the Console.
Go to each sensor and press its test button or
open and close the protected opening.
To test the wireless keypad, press the [
(A)
] key.
The Console will make a “bing” sound as each
sensor is tested.
As each sensor is tested, the sensor status
light for the sensor will stop flashing and
return to showing the current status of the
sensor.
Continue testing until there are no flashing
status lights.
NOTE: If the Console is left unattended in Test
Mode, it will automatically switch back to Off Mode
after 3 minutes.
When directly connecting (without a telephone
line) to the DVS-1200 with the RA-2400
remote access software (Version 1.3 or later),
press the [
EMERGENCY
] key while in Test
Mode to cause the Console to connect to the
modem.
START IN OFF
YOUR
USER
CODE
DONE
1 GONG
& 4 BEEPS
(OPTIONAL)
TEST MODE
TEST
SENSOR FUNCTION IN EACH CONSOLE MODE
SENSOR TYPE OFF MODE CHIME MODE HOME MODE AWAY MODE
AUTOMATION ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT
EMERGENCY ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM
PANIC ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM
FIRE ARMED 24-HOURS - TRIGGERS FIRE ALARM
PERIMETER DEACTIVATED CHIME INSTANT BURGLARY ALARM
EXIT/ENTRY DEACTIVATED CHIME DELAYED BURGLARY ALARM
INTERIOR DEACTIVATED DEACTIVATED DEACTIVATED
FOLLOWER
(INSTANT BURGLARY ALARM
UNLESS ACTIVATED DURING
ENTRY DELAY)
CHIME CHIME
2-BUTTON ARM/DISARM (LEFT)
2-BUTTON AUTOMATION (RIGHT)
EMERGENCY (BOTH)
LEFT BUTTON SWITCHES CONSOLE TO AWAY OR HOME MODE
(PROGRAMMING FUNCTION 50)
IF ALARM MEMORY IS ACTIVE, SWITCHES CONSOLE TO OFF OR
CHIME MODE (PROGRAMMING FUNCTION 51)
LEFT BUTTON SWITCHES TO OFF OR CHIME MODE
(PROGRAMMING FUNCTION 51)
2-BUTTON ARM (LEFT)
2-BUTTON DISARM (RIGHT)
LEFT BUTTON SWITCHES CONSOLE TO AWAY OR HOME MODE
(PROGRAMMING FUNCTION 50)
IF ALARM MEMORY IS ACTIVE, SWITCHES CONSOLE TO OFF OR
CHIME MODE (PROGRAMMING FUNCTION 51)
RIGHT BUTTON SWITCHES TO OFF OR CHIME MODE
(PROGRAMMING FUNCTION 51)
ENVIRONMENTAL ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY
Console Zone Table