Black 0021
Black0021
AWAY MODE
◆ Use this mode when no one will be staying home.
◆ Each burglary sensor can trigger the siren once
per arming period.
◆ Away Mode causes an instant alarm when any
perimeter sensor is triggered.
◆ Away Mode causes a delayed alarm when any
exit/entry sensor is triggered.
◆ Away Mode causes an instant alarm when any
interior sensors (motion detectors, etc.) are
triggered. The interior sensors will be delayed if a
perimeter delayed sensor is triggered first.
◆ Alarm siren stops automatically after five minutes
and the system will remain armed.
Arm to Away Mode by entering a user code, and
pressing [
AWAY
].
The user can “Quick Arm” to Away Mode from
Home, Chime or Off Mode by holding down the
[
AWAY
] key for two seconds. (Quick arming can
be disabled; see the “Advanced Programming”
section of this manual.)
EXIT DELAY (For Leaving the Premises)
❇ When the system is armed to the Away Mode, the
Console will sound a “Gong” and three “Beeps”.
❇ During the 60 second Exit Delay, the Console will
sound “beeps” (double beeps last 10 seconds) and
the AWAY light will blink.
◆ The Exit Delay gives the user 60 seconds to leave
the premises
through an exit/entry door without
triggering an alarm.
◆ Re-entering during the Exit Delay will extend the
Exit Delay another 60 seconds (one time only).
❇ When the Exit Delay is over, the Console will
sound one “gong” to warn the user that the
system is fully armed.
✍
NOTE: The Exit Delay time can be changed; see the
“Advanced Programming” section of this manual.
ENTRY DELAY (For Entering the Premises)
◆ The Entry Delay gives the user 30 seconds to
enter the premises
through an exit/entry door
without triggering an alarm.
◆ If a exit/entry sensor is triggered, starting the Entry
Delay, the interior sensors will also become
delayed (this allows motion in the premises during
the Entry Delay).
❇ During the 30 second Entry Delay, the Console
will sound “beeps”.
◆ When the Entry Delay is over, the Console will go
into full alarm and sound the siren if it is not
disarmed to the Off or Chime Mode.
❇ If an alarm has occurred while the user was gone,
multiple beeps will sound after disarming and the
sensor light for the sensor(s) that caused the alarm
will flash (switch to Off Mode again or re-arm the
Console to stop the flashing alarm memory light).
✍
NOTE: The Entry Delay time can be changed; see the
“Advanced Programming” section of this manual.
MANUAL BYPASSING OF SENSORS
◆ Manual bypassing of sensors in the Away
Mode allows arming of the system with open
doors and windows, while still having
perimeter protection with other closed doors
and windows.
◆ The Console will resist arming with open door
or window sensors.
❇ Four high-low beeps to warn the user that
something is open and the system will remain
in the previous mode.
❇ Lit sensor status indicators show which
sensors are open.
To manually bypass the open sensors, arm
the system again within 5 seconds.
❇ A “gong” and three “beeps” will sound, the
AWAY indicator will light, and the open
sensors will be bypassed.
✍
WARNING: Bypassed sensors cannot cause an
alarm.
START HERE
DONE
1 GONG
& 3 BEEPS
HOLD
DOWN
START HERE
YOUR
USER
CODE
DONE
1 GONG
& 3 BEEPS
(OPTIONAL)
AWAY MODE
AWAY
AWAY
QUICK ARM
19