6 - 22
No. 99MBC032A
6.2 Digimatic Output Unit interface
With the Digimatic Output Unit interface the LSM can be connected to the Digimatic Data
Processor (DP-1HS, etc.) which uses the Mitutoyo-original data format for easy data collec-
tion and processing.
6.2.1 Method of use
1) In the B6 mode of the basic setup, make the settings for the Digimatic Output Unit interface.
: The Digimatic Output Unit interface is valid.
• Set the data output conditions in the function setup.
Data output condition Printer
RS-232C
DCU
Remark
The periodical output timer can be set
0
1
2
7
——
—
—
—
—
8
9
6
The periodical output timer can be set5
4
The periodical output timer can be set3
: Outputs data for each measurement.
: Performs measurement and outputs data when a GO measurement results.
: Performs measurement and outputs data when a ±NG measurement results.
: No output
—
—
—
2) Data output
a. When a data send request comes from the external equipment such as the Digimatic Data
Processor to the LSM, the measurement data will be outputted through this interface by
the following timing.
• When the
DATA
key on the Digimatic Data Processor is pressed
• When the foot switch being connected to the Digimatic Data Processor is pressed.
• When an REQ signal is inputted from other external equipment.
b. When the measurement is initiated by pressing the
RUN
key or “R” command from the
RS-232C interface, the measurement data will be outputted according to the data output
conditions being set.