HP (Hewlett-Packard) 8935 Cell Phone Accessories User Manual


 
Chapter 2 39
Testing AMPS Base Stations
Transmitter Data Deviation
Chapter 2
Testing AMPS Base Stations
8. Set Filter 1 to <20Hz HPF.
9. Set Filter 2 to >99kHz LP.
10.Press the
RF Anl key to access the RF ANALYZER screen.
11.Enter the transmitter’s channel number in the RF Channel field.
12. Turn on the transmitter. The FM Deviation from the data is
displayed.
Figure 2-5 Data Deviation Test Results
<20Hz HPF
>99kHz LPF
Data Deviation
Main Menu