BMC Software, Inc., Confidential and Proprietary Information
BMC74400–BMC74499 247
260
BMC74400–BMC74499
BMC74400I APPLICATION ENHANCEMENT SERIES ABORTING
Explanation: The Application Enhancement Solutions (AES) application
supervisor has encountered an error condition that prohibits continued processing.
The job log contains additional messages that indicate the failure encountered.
Note: When this message is written to the job log data set, it appears in a box to
highlight the need for manual assistance with the job step.
System Action: The job step terminates abnormally when the AES application
supervisor is active and the Initialization Error option (set at the AES global level) is
set to
OPTION=ABEND. If the Initialization Error option is set to OPTION=IMS, the
job step returns control to IMS and continues processing without AES.
User Response: The job log data set should contain additional information about
the reason for aborting. If the job step abends, correct the problem identified in these
messages prior to resubmitting the job step. Have the job log data set available if you
need to contact BMC Software Product Support for assistance.
BMC74401E LOAD FAILED FOR MODULE=module
Explanation: The Application Enhancement Solutions (AES) application
supervisor has detected an error while attempting to load the given module.
System Action: The action taken depends on the module being loaded. Additional
messages are issued to provide more information on the error.
User Response: Ensure that the modules necessary for AES execution are
available. See the section on customized modules in the Application Enhancement
Solutions Installation Guide for more information. Have the job log data set
available if you need to contact BMC Software Product Support for assistance.