BMC150079E CANNOT RESTORE WORKING STORAGE AT FIRST COMMIT WHEN
USING AUTO CHECKPOINTING
Explanation: When using the Automatic Checkpoints option, the application
program cannot contain SQL commits; therefore, the working storage cannot be
restored at the first commit.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues without AR/CTL.
User Response: Ensure that the Automatic Checkpoints option is set to N.
BMC150080E AUTO RESTART AND AUTO CHECKPOINT NOT ALLOWED WITH VSAM
FILE SHARING ONLY
Explanation: When using the VSAM File Sharing Only option, the Automatic
Restart option and Automatic Checkpoints option must be set to N.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues without AR/CTL.
User Response: Ensure that the Automatic Restart option and the Automatic
Checkpoints option are set to N.
BMC150081E MORE THAN ONE TRIGGER WAS SPECIFIED FOR AUTOMATIC
RESTART AND AUTOMATIC CHECKPOINT
Explanation: When using the Automatic Restart option and the Automatic
Checkpoints option, only one trigger option can be specified. The Trigger DDname
option and the Trigger Cursor Name option are mutually exclusive.
System Action: If the Application Enhancement Solutions Force AR/CTL
Execution option is set to Y, the job step terminates abnormally with abend U1553. If
this option is set to N, the job step continues without AR/CTL.
User Response: Ensure that only one trigger option is specified for the Automatic
Restart option and the Automatic Checkpoint option.