A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
78 Application Enhancement Solutions Messages Manual
System Action: The action taken depends on the reason for the message.
User Response: The response depends on the reason code:
01 If the IMS IEFRDER DD statement is not specified as DUMMY, contact
BMC Software Product Support for assistance.
02 Make sure the modules needed for BCF execution are available.
03 Make sure the modules needed for BCF execution are available.
04 Verify that the region type is not an IMS type 3 batch region
(DLI, DBB, or ULU). If the region type is not batch, ignore the message.
Otherwise, contact BMC Software Product Support for assistance.
05 Initialization is not attempted. Use native IMS routines.
06 Initialization is not attempted. Use native IMS routines.
07 Locate IMS module DFSXLGI0 and ensure that it is in the STEPLIB
concatenation.
08 Verify the level of IMS. If it is a supported IMS level, contact BMC
Software Product Support for assistance.
09 Verify that BCF is authorized to execute on the processor. If you are using a
trial copy, verify that the expiration date has not passed. The job log may
contain additional messages to explain the BCF Physical Logger failure.
10 Remove the library containing BCF modules from the JCL procedure being
executed.
11 Initialization is not attempted. Use native IMS routines.
12 Make sure the AES modules needed for execution are available to the job
step.
BMC44206I IMS LOG TERMINATED
Explanation: The BATCH CONTROL FACILITY (BCF) Physical Logger has
closed the IMS log. This message replaces the IMS DFS092I message.
System Action: Processing continues.
User Response: This message is for your information only. No action is necessary.