bits 4-2 Number of Bits-Per-Pixel Select Bits [2:0]
These bits select the number of bits-per-pixel (bpp) for the displayed data.
Note
15 and 16-bpp modes bypass the LUT and are supported as 12-bpp on passive panels and 15/16-
bpp on TFT panels. These modes are not supported on CRT. See Figure 10-2: “15/16 Bit-Per-
Pixel Format Memory Organization,” on page 117 for a description of passive panel support.
bit 1 CRT Enable
This bit enables the CRT control signals.
Note
REG[02h] bit 1 must = 0 when in CRT only mode.
bit 0 LCD Enable
This bit enables the LCD control signals. Programming this bit from a 0 to a 1 starts the LCD
power-on sequence. Programming this bit from a 1 to a 0 starts the LCD power-off sequence.
Table 8-7: Number of Bits-Per-Pixel Selection
Number Of Bits-Per-Pixel Select Bits [2:0] Number of Bits-Per-Pixel
000 1
001 2
010 4
011 8
100 15
101 16
110-111 Reserved